Integrated Controls, Inc.
Integrated Controls, Inc. Home Control Panels, Sensors, Flow Control, Skid Mount, Fresh Water, Wastewater,VFDs Turnkey System Design and Build, Instrumentation and Control, Programming, Calibration, and Upgrades Corporate Login for Integrated Controls, Inc. Contact Integrated Controls, Inc.

MAG-METERS

SENSORS

PRODUCT INDEX

LINE CARD
CUSTOM PUMPING SOLUTIONS

I & C ENGINEERING

PROGRAMMING

CALIBRATION

UPGRADES
SEARCH

CONTACT ICI
TOLL FREE AT

866-ICI PROC
866-424-7762

PARTI-MAGS

Looking for a way to measure a partially full pipe? Then a parti-mag is your answer. Integrated Controls, Inc. supplies electromagnetic meters to measure the flow for drainage control, metering, and monitoring.

METER PARTAILLY FULL PIPE LINES

Meter Without Inverts & Large Downward Slopes
Easy Installation
No On-Site Callibration
High Accuracy Even for Low Fill Levels
Maintenance Free System
No Mechanical Wear
No Pressure Drop
No Moving Parts or Restrictions in the Meter

ABB Parti-Mag FXP4000
Shown above is ABB's FXP4000 Parti-mag
PROCESS RELIABILITY
  • Flow rate indication and flow totalization
  • Wide flow ranges from 0.5 and 10 m/s
  • Pulse isolated by galvanization and current outputs
  • Large variety of output signals increase system reliability and decrease down times
  • Communication capability provides continuous system monitoring with automatic error diagnostics
  • Redundant measurement values are continuously monitored for plausibility by the system monitor in the converter
  • Messages appear in clear text on the display and are signaled over a contact output.
DESIGN FEATURES
  • Microprocessor converter with flowrate indication and totalization
  • Engineered especially for flow metering in partially full pipelines
  • Unaffected by backflow during partially full flow
  • Short in and outlet straight sections:
    5xDN upstream
    3xDN downstream of the meter
  • Required fill level 10% of the flow meter diameter
  • Output signal cutoff activated if level drops below minimum fill level
  • Factory calibrated
  • Automatic system monitoring with error diagnostics and output alarm signal
  • Exceptional accuracy with long term stability
  • Accuracy:
    partially full pipes: 3% or 5% of rate
    full pipe: 1% of rate
 

For product specifications, click on the button below to view a pdf file. If you would like to order a parti-mag, call Integrated Controls, Inc. now for pricing.

View Parti-Mag PDF
view a pdf

 

 

Integrated Controls, Inc